Drymatic II Machine Calculation

Drying Room Length (M)
Drying Room Width (M)
Drying Room Height (M)
Class of Water Loss
Number of D2s Required to Achieve Recommended ACHs:

kW/BTU Calculator

Volume (M3)
Inside Temperature (C)
Desired Temperature (C)
Outside Temperature (C)
Class of Water Loss
BTU's Required:
KW Required:

Running cost calculator - UK

Equipment
Number of Hours Run
Energy Tariff Per kWh in £
Estimated Running Cost in the UK:

Running cost calculator - US

Equipment
Number of Hours Run
Energy Tariff Per kWh in US$
Estimated Running Cost In the US:

Running Cost Calculator - Australia

Equipment
Number of Hours Run
Energy Tariff Per kWh in AU$
Estimated Running Cost in Australia:

Running Cost Calculator - Europe

Equipment
Number of Hours Run
Energy Tariff Per kWh in Euro
Estimated Running Cost in Europe:

Definitions of each Class of Water Damage

Class 1 : Slow Rate of Evaporation – Least amount of water absorption and evaporation load

  • Water intrusion where low porosity materials (e.g hard surface flooring, plaster, concrete) or medium porosity materials (e.g structural framing, wood substrates) have absorbed minimal moisture.

  • Less than 5% of the combined floor, wall and ceiling surface area in the space is wet, highly porous material (e.g carpet, plasterboard)


Class 2: Fast Rate of Evaporation – Significant amount of water absorption and evaporation load

  • Water intrusion where wet, highly porous materials (e.g carpet, plasterboard) represent more than 5%, but less than 50% of the combined floor, wall and ceiling surface area in the space.

 
Class 3: Fastest Rate of Evaporation – Greatest amount of water absorption and evaporation load

  • Water intrusion where wet, highly porous materials (e.g carpet, plasterboard) represent more than 50% of the combined floor, wall and ceiling surface area in the space

 
Class 4 : Specialty Drying Situations – Deeply held or bound water

  • A water intrusion that involves a significant amount of water and absorption into low porosity materials (e.g hard surface flooring, plaster, concrete) or assemblies (gymnasium floors, structural cavities, multiple layers of plasterboard) that have a low rate of evaporation due to deeply held or bound water. Drying may require special methods, longer drying times, or substantial vapor pressure differentials.

Other Considerations:

Other factors can impact the drying environment. Restorers should understand and consider these factors when estimating the drying capacity needed to prevent additional damages and begin the drying process. These factors include:

  • Influence of heating, ventilating, and air conditioning (HVAC) systems

  • Build-out density of the affected area

  • Building construction and complexity

  • Influence of outdoor weather conditions